{"id":34441,"date":"2026-08-05T13:41:39","date_gmt":"2026-08-05T10:41:39","guid":{"rendered":"https:\/\/qariya.net\/?post_type=product&#038;p=34441"},"modified":"2026-08-05T13:47:24","modified_gmt":"2026-08-05T10:47:24","slug":"ntc-thermistor-negative-temperature-coefficient-inrush-current-limiter","status":"publish","type":"product","link":"https:\/\/qariya.net\/en\/product\/ntc-thermistor-negative-temperature-coefficient-inrush-current-limiter\/","title":{"rendered":"NTC Thermistor (Negative Temperature Coefficient) \u2013 Inrush Current Limiter"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1s6nnkh\" data-start=\"152\" data-end=\"233\"><span role=\"text\"><strong data-start=\"155\" data-end=\"233\">NTC Thermistor (Negative Temperature Coefficient) \u2013 Inrush Current Limiter<\/strong><\/span><\/h2>\n<p data-start=\"235\" data-end=\"649\">The <strong data-start=\"239\" data-end=\"257\">NTC Thermistor<\/strong> (Negative Temperature Coefficient) is a temperature-sensitive resistor whose resistance decreases as temperature increases. It is commonly used as an <strong data-start=\"408\" data-end=\"440\">Inrush Current Limiter (ICL)<\/strong> to reduce the high surge current that occurs when electrical equipment is first powered on, helping protect power supplies, transformers, motors, and electronic circuits.<\/p>\n<p data-start=\"651\" data-end=\"754\">Available in multiple resistance values and disc sizes to meet different current-handling requirements.<\/p>\n<h3 data-section-id=\"1kmvnsz\" data-start=\"756\" data-end=\"780\"><span role=\"text\"><strong data-start=\"760\" data-end=\"780\">Available Models<\/strong><\/span><\/h3>\n<ul data-start=\"781\" data-end=\"960\">\n<li data-section-id=\"1wogmfs\" data-start=\"781\" data-end=\"791\">NTC 5D-5<\/li>\n<li data-section-id=\"1wogmfu\" data-start=\"792\" data-end=\"802\">NTC 5D-7<\/li>\n<li data-section-id=\"1wogmfo\" data-start=\"803\" data-end=\"813\">NTC 5D-9<\/li>\n<li data-section-id=\"1sgqvcd\" data-start=\"814\" data-end=\"825\">NTC 5D-11<\/li>\n<li data-section-id=\"1sgqvc9\" data-start=\"826\" data-end=\"837\">NTC 5D-15<\/li>\n<li data-section-id=\"1wonmrd\" data-start=\"838\" data-end=\"848\">NTC 8D-9<\/li>\n<li data-section-id=\"1sn65nk\" data-start=\"849\" data-end=\"860\">NTC 8D-11<\/li>\n<li data-section-id=\"1sn65mq\" data-start=\"861\" data-end=\"872\">NTC 8D-20<\/li>\n<li data-section-id=\"1sf0bxq\" data-start=\"873\" data-end=\"884\">NTC 10D-7<\/li>\n<li data-section-id=\"1sf0bxc\" data-start=\"885\" data-end=\"896\">NTC 10D-9<\/li>\n<li data-section-id=\"1tv1cgp\" data-start=\"897\" data-end=\"909\">NTC 10D-11<\/li>\n<li data-section-id=\"1tv1cgt\" data-start=\"910\" data-end=\"922\">NTC 10D-15<\/li>\n<li data-section-id=\"1tv1cl7\" data-start=\"923\" data-end=\"935\">NTC 10D-20<\/li>\n<li data-section-id=\"1x23060\" data-start=\"936\" data-end=\"948\">NTC 20D-20<\/li>\n<li data-section-id=\"1sghdsf\" data-start=\"949\" data-end=\"960\">NTC 33D-7<\/li>\n<\/ul>\n<h3 data-section-id=\"kylm4h\" data-start=\"962\" data-end=\"978\"><span role=\"text\"><strong data-start=\"966\" data-end=\"978\">Features<\/strong><\/span><\/h3>\n<ul data-start=\"979\" data-end=\"1280\">\n<li data-section-id=\"2083j3\" data-start=\"979\" data-end=\"1030\">Negative Temperature Coefficient (NTC) thermistor<\/li>\n<li data-section-id=\"1r49cr0\" data-start=\"1031\" data-end=\"1070\">Limits inrush current during power-on<\/li>\n<li data-section-id=\"1c7vff7\" data-start=\"1071\" data-end=\"1118\">Resistance decreases as temperature increases<\/li>\n<li data-section-id=\"1u94uqd\" data-start=\"1119\" data-end=\"1176\">Improves circuit reliability and extends component life<\/li>\n<li data-section-id=\"m819uo\" data-start=\"1177\" data-end=\"1200\">Fast thermal response<\/li>\n<li data-section-id=\"qhtt7d\" data-start=\"1201\" data-end=\"1236\">Radial lead, through-hole package<\/li>\n<li data-section-id=\"1f35vdm\" data-start=\"1237\" data-end=\"1280\">Suitable for AC and DC power applications<\/li>\n<\/ul>\n<h3 data-section-id=\"1lhszvz\" data-start=\"1282\" data-end=\"1302\"><span role=\"text\"><strong data-start=\"1286\" data-end=\"1302\">Applications<\/strong><\/span><\/h3>\n<ul data-start=\"1303\" data-end=\"1469\">\n<li data-section-id=\"1uinfl8\" data-start=\"1303\" data-end=\"1336\">Switching power supplies (SMPS)<\/li>\n<li data-section-id=\"lj245a\" data-start=\"1337\" data-end=\"1355\">Battery chargers<\/li>\n<li data-section-id=\"19xqucz\" data-start=\"1356\" data-end=\"1372\">Power adapters<\/li>\n<li data-section-id=\"a2ea0w\" data-start=\"1373\" data-end=\"1387\">Transformers<\/li>\n<li data-section-id=\"1t9uh64\" data-start=\"1388\" data-end=\"1407\">Motor controllers<\/li>\n<li data-section-id=\"1eumui7\" data-start=\"1408\" data-end=\"1428\">LED power supplies<\/li>\n<li data-section-id=\"16wih39\" data-start=\"1429\" data-end=\"1451\">Industrial equipment<\/li>\n<li data-section-id=\"1ne8eqh\" data-start=\"1452\" data-end=\"1469\">Home appliances<\/li>\n<\/ul>\n<p data-start=\"1471\" data-end=\"1494\"><strong data-start=\"1471\" data-end=\"1494\">Model Number Guide:<\/strong><\/p>\n<ul data-start=\"1495\" data-end=\"1729\">\n<li data-section-id=\"1dbsqfw\" data-start=\"1495\" data-end=\"1567\">The number before <strong data-start=\"1515\" data-end=\"1520\">D<\/strong> indicates the <strong data-start=\"1535\" data-end=\"1566\">cold resistance at 25\u00b0C (\u03a9)<\/strong>.<\/li>\n<li data-section-id=\"xisfx9\" data-start=\"1568\" data-end=\"1729\">The number after <strong data-start=\"1587\" data-end=\"1592\">D<\/strong> indicates the approximate <strong data-start=\"1619\" data-end=\"1641\">disc diameter (mm)<\/strong>, which is related to current-handling capability.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>NTC Thermistor (Negative Temperature Coefficient) \u2013 Inrush Current Limiter The NTC Thermistor (Negative Temperature Coefficient) is a temperature-sensitive resistor whose resistance decreases as temperature increases. It is commonly used as an Inrush Current Limiter (ICL) to reduce the high surge current that occurs when electrical equipment is first powered on, helping protect power supplies, transformers, [&hellip;]\n","protected":false},"featured_media":34490,"template":"","meta":[],"product_cat":[210,169],"product_tag":[],"_links":{"self":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product\/34441"}],"collection":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/media\/34490"}],"wp:attachment":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/media?parent=34441"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product_cat?post=34441"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product_tag?post=34441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}