{"id":24393,"date":"2023-04-09T23:02:52","date_gmt":"2023-04-09T20:02:52","guid":{"rendered":"https:\/\/qariya.net\/?post_type=product&#038;p=24393"},"modified":"2026-03-24T12:31:12","modified_gmt":"2026-03-24T09:31:12","slug":"fluke-digital-meter","status":"publish","type":"product","link":"https:\/\/qariya.net\/en\/product\/fluke-digital-meter\/","title":{"rendered":"Fluke Digital Multi Meter Model 106+"},"content":{"rendered":"<h1>FLUKE DIGITAL MULTI METER MODEL 106+<\/h1>\n<div class=\"panel panel-default\">\n<div id=\"resources-data-sheets-list\" class=\"panel-collapse collapse\" role=\"tabpanel\" aria-labelledby=\"resources-data-sheets-title\" aria-expanded=\"false\">\n<div class=\"panel-body\"><\/div>\n<\/div>\n<\/div>\n<p><a href=\"https:\/\/www.fluke.com\/en-in\/product\/electrical-testing\/digital-multimeters\/fluke-106\/ds\"><strong>Download Fluke 106 Palm-sized Digital Multimeter | Data sheets<\/strong><\/a><\/p>\n<p>Voltage, resistance, continuity, capacitance<\/p>\n<p>Input terminal for AC and DC current measurements to 10 A and current<br \/>\nData hold<\/p>\n<h2>Specifications: Fluke 106 Palm-sized Digital Multimeter<\/h2>\n<div id=\"fluke-product-display-specs\">\n<div id=\"product-specs\">\n<div id=\"specification_content\">\n<div class=\"clickability\">\n<p>Accuracy is specified for 1 year after calibration, at operating temperatures of 18 \u00b0C to 28 \u00b0C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: \u00b1([% of Reading] + [Number of Least Significant Digits])<\/p>\n<table>\n<tbody>\n<tr class=\"head\">\n<td colspan=\"5\">Accuracy Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"40%\">Function<\/td>\n<td width=\"20%\"><strong>Range<\/strong><\/td>\n<td width=\"20%\"><strong>Resolution<\/strong><\/td>\n<td width=\"20%\"><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">AC Volts<br \/>\n(40 Hz to 500Hz)<sup>1<\/sup><\/td>\n<td>6.000 V<br \/>\n60.00 V<br \/>\n600.0 V<\/td>\n<td>0.001 V<br \/>\n0.01 V<br \/>\n0.1 V<\/td>\n<td>1.0 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">DC Volts<\/td>\n<td>6.000 V<br \/>\n60.00 V<br \/>\n600.0 V<\/td>\n<td>0.001 V<br \/>\n0.01 V<br \/>\n0.1 V<\/td>\n<td>0.5 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">AC Millivolts<\/td>\n<td>600.0 mV<\/td>\n<td>0.1 mV<\/td>\n<td>3.0 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Diode Test<sup>2<\/sup><\/td>\n<td>2.000 V<\/td>\n<td>0.001 V<\/td>\n<td>10 %<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Resistance<br \/>\n(Ohms)<\/td>\n<td>400.0 \u03a9<br \/>\n4.000 k\u03a9<br \/>\n40.00 k\u03a9<br \/>\n400.0 k\u03a9<br \/>\n4.000 M\u03a9<br \/>\n40.00 M\u03a9<\/td>\n<td>0.1 \u03a9<br \/>\n0.001 k\u03a9<br \/>\n0.01 k\u03a9<br \/>\n0.1 k\u03a9<br \/>\n0.001 M\u03a9<br \/>\n0.01 M\u03a9<\/td>\n<td>0.5 % + 3<br \/>\n0.5 % + 2<br \/>\n0.5 % + 2<br \/>\n0.5 % + 2<br \/>\n0.5 % + 2<br \/>\n1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Capacitance<sup>3<\/sup><\/td>\n<td>50.00 nF<br \/>\n500.0 nF<br \/>\n5.000 \u03bcF<br \/>\n50.00 \u03bcF<br \/>\n500.0 \u03bcF<br \/>\n1000 \u03bcF<\/td>\n<td>0.01 nF<br \/>\n0.1 nF<br \/>\n0.001 \u03bcF<br \/>\n0.01 \u03bcF<br \/>\n0.1 \u03bcF<br \/>\n1 \u03bcF<\/td>\n<td>2 % + 5<br \/>\n2 % + 5<br \/>\n5 % + 5<br \/>\n5 % + 5<br \/>\n5 % + 5<br \/>\n5 % + 5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Frequency<sup>4<\/sup>\u00a0Hz<br \/>\n(10 Hz \u2013 100 kHz)<\/td>\n<td>50.00 Hz<br \/>\n500.0 Hz<br \/>\n5.000 kHz<br \/>\n50.00 kHz<br \/>\n100.0 kHz<\/td>\n<td>0.01 Hz<br \/>\n0.1 Hz<br \/>\n0.001 kHz<br \/>\n0.01 kHz<br \/>\n0.1 kHz<\/td>\n<td>NA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Duty Cycle<sup>4<\/sup><\/td>\n<td>1 % to 99 %<\/td>\n<td>0.1 %<\/td>\n<td>NA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">AC Current<br \/>\n(40 Hz to 200 Hz)<\/td>\n<td>4.000 A<br \/>\n10.00 A<\/td>\n<td>0.001 A<br \/>\n0.01 A<\/td>\n<td>1.5 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">DC Current<\/td>\n<td>4.000 A<br \/>\n10.00 A<\/td>\n<td>0.001 A<br \/>\n0.01 A<\/td>\n<td>1.5 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<ol>\n<li>All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.<\/li>\n<li>Typically, open circuit test voltage is 2.0 V and short circuit current is &lt;0.6 mA.<\/li>\n<li>Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).<\/li>\n<li>All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\">Function<\/td>\n<td width=\"20%\"><strong>Overload Protection<\/strong><\/td>\n<td width=\"20%\"><strong>Input Impedance (Nominal)<\/strong><\/td>\n<td width=\"20%\"><strong>Common Mode Rejection Ratio<\/strong><\/td>\n<td width=\"20%\"><strong>Normal Mode Rejection Ratio<\/strong><\/td>\n<\/tr>\n<tr>\n<td>AC Volts<\/td>\n<td>600 V\u00a0<sup>1<\/sup><\/td>\n<td>&gt;10 M\u03a9 &lt;100 pF\u00a0<sup>2<\/sup><\/td>\n<td>&gt;60 dB at dc,<br \/>\n50 Hz or 60 Hz<\/td>\n<td>\u2212<\/td>\n<\/tr>\n<tr>\n<td>\\AC Millivolts<\/td>\n<td>600 mV<\/td>\n<td>&gt;1M, &lt;100 pF<\/td>\n<td>&gt;80 dB at 50 Hz or 60 Hz<\/td>\n<td>\u2212<\/td>\n<\/tr>\n<tr>\n<td>DC Volts<\/td>\n<td>600 V\u00a0<sup>1<\/sup><\/td>\n<td>&gt;10 M\u03a9 &lt;100 pF<\/td>\n<td>&gt;100 dB at dc,<br \/>\n50 Hz or 60 Hz<\/td>\n<td>&gt;60 dB at 50 Hz or 60 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<ol>\n<li>6 x 105 V Hz Max<\/li>\n<li>For mV (AC), input impedance is approximately 1 M\u03a9.<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">General Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Maximum Voltage Between any Terminal and Earth Ground<\/td>\n<td colspan=\"3\">600 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Display (LCD)<\/td>\n<td colspan=\"3\">6000 counts, updates 3\/sec<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Battery Type<\/td>\n<td colspan=\"3\">2 AAA, NEDA 24A, IEC LR03<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Battery Life<\/td>\n<td colspan=\"3\">200 hours minimum<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Temperature<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating<\/td>\n<td colspan=\"3\">0 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Storage<\/td>\n<td colspan=\"3\">-30 \u00b0C to 60 \u00b0C<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Relative Humidity<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating Humidity<\/td>\n<td colspan=\"3\">Non-condensing when &lt;10\u00b0C<br \/>\n\u226490 % at 10 \u00b0C to 30 \u00b0C; \u226475 % at 30 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating Humidity, 40 M\u03a9 Range<\/td>\n<td colspan=\"3\">\u226480 % at 10 \u00b0C to 30 \u00b0C; \u226470 % at 30 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Altitude<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating<\/td>\n<td colspan=\"3\">2000 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Storage<\/td>\n<td colspan=\"3\">12,000 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Temperature Coefficient<\/td>\n<td colspan=\"3\">0.1 X (specified accuracy) \/\u00b0C (&lt;18 \u00b0C or &gt;28 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Fuse Protection for Current Inputs<\/td>\n<td colspan=\"3\">11A, 1000V Fast Fuse, Fluke specified part only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Size (HxWxL)<\/td>\n<td colspan=\"3\">142 mm x 69 mm x 28mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Weight<\/td>\n<td colspan=\"3\">200 g<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">IP Rating<\/td>\n<td colspan=\"3\">IEC 60529: IP 40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Safety<\/td>\n<td colspan=\"3\">IEC 61010-1: 600 V CAT III, Pollution Degree 2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic Environment<\/td>\n<td colspan=\"3\">IEC 61326-1: Portable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Electromagnetic Compatibility<\/td>\n<td colspan=\"3\">Applies to use the Korea only.\u00a0 Class A Equipment (Industrial Broadcasting and Communication Equipment)<sup>1<\/sup><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<ol>\n<li>This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>FLUKE DIGITAL MULTI METER MODEL 106+ Download Fluke 106 Palm-sized Digital Multimeter | Data sheets Voltage, resistance, continuity, capacitance Input terminal for AC and DC current measurements to 10 A and current Data hold Specifications: Fluke 106 Palm-sized Digital Multimeter Accuracy is specified for 1 year after calibration, at operating temperatures of 18 \u00b0C to [&hellip;]\n","protected":false},"featured_media":24406,"template":"","meta":[],"product_cat":[210,169],"product_tag":[],"_links":{"self":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product\/24393"}],"collection":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/media\/24406"}],"wp:attachment":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/media?parent=24393"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product_cat?post=24393"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product_tag?post=24393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}