{"id":24387,"date":"2023-04-09T22:48:36","date_gmt":"2023-04-09T19:48:36","guid":{"rendered":"https:\/\/qariya.net\/?post_type=product&#038;p=24387"},"modified":"2025-06-03T14:14:25","modified_gmt":"2025-06-03T11:14:25","slug":"fluke-digital-multi-meter-model-15b","status":"publish","type":"product","link":"https:\/\/qariya.net\/en\/product\/fluke-digital-multi-meter-model-15b\/","title":{"rendered":"Fluke Digital Multi Meter Model 15B+"},"content":{"rendered":"<h1 class=\"product-title entry-title\">FLUKE DIGITAL MULTI METER MODEL15B+<\/h1>\n<div id=\"shopify-section-static-product\" class=\"shopify-section product--section\">\n<section class=\"product--container layout--two-col\" data-product-wrapper=\"\">\n<div class=\"container\">\n<div class=\"sixteen columns\">\n<div id=\"London\" class=\"tabcontent\">\n<div class=\"main-container \">\n<div id=\"block-system-main\" class=\"block block-system \">\n<div class=\"panel-display ryan clearfix flukestrap-ryan\">\n<div class=\"ryan-content\">\n<div class=\"panel-pane pane-block pane-igcommerce-utility-products-product-detail-page pane-igcommerce-utility-products\">\n<div class=\"pane-content\">\n<article id=\"fluke-product-display\" class=\"template-F4 nid-6658 spid-\">\n<div id=\"fluke-product-display-content-tabs\">\n<div class=\"gray-wrapper\">\n<div class=\"container\">\n<div class=\"tab-content\">\n<div id=\"specs-tab\" class=\"tab-pane active\" tabindex=\"0\" role=\"tabpanel\" aria-labelledby=\"specs-label\">\n<section><a href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6002719_0000_ENG_A_W.PDF\"><strong>Download FLUKE 15B+ 17B+ Data Sheet<\/strong><\/a><br \/>\n\u25cf\u00a0600V Cat III safety rating<br \/>\n\u25cf\u00a050% bigger display with bright white backlight<br \/>\n\u25cf\u00a0Voltage, resistance, continuity, capacitance<br \/>\n\u25cf\u00a0Input terminal for ac and dc current measurements to 10A current<br \/>\n\u25cf\u00a0Diode test, and Data hold<\/p>\n<h2>Specifications: Fluke 15B+ Digital Multimeter<\/h2>\n<div id=\"fluke-product-display-specs\">\n<div id=\"product-specs\">\n<div id=\"specification_content\">\n<h2>Accuracy Specifications<\/h2>\n<p>Accuracy is specified for 1 year after calibration, at operating temperatures of 18 \u00b0C to 28 \u00b0C, relative humidity at 0% to 75%. Accuracy specifications take the form of: \u00b1(% of Reading + Number of Least Significant Digits).<\/p>\n<table>\n<tbody>\n<tr>\n<td>Function<\/td>\n<td>Range<\/td>\n<td>Resolution<\/td>\n<td>Accuracy<\/td>\n<\/tr>\n<tr>\n<td>AC volts<br \/>\n(40 Hz to 500Hz)<sup>1<\/sup><\/td>\n<td>4.000 V<br \/>\n40.00 V<br \/>\n400.0 V<br \/>\n1000 V<\/td>\n<td>0.001 V<br \/>\n0.01 V<br \/>\n0.1 V<br \/>\n1 V<\/td>\n<td>1.0% + 3<\/td>\n<\/tr>\n<tr>\n<td>DC volts<\/td>\n<td>4.000 V<br \/>\n40.00 V<br \/>\n400.0 V<br \/>\n1000 V<\/td>\n<td>0.001 V<br \/>\n0.01 V<br \/>\n0.1 V<br \/>\n1 V<\/td>\n<td>0.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>AC millivolts<\/td>\n<td>400.0 mV<\/td>\n<td>0.1 mV<\/td>\n<td>3.0% + 3<\/td>\n<\/tr>\n<tr>\n<td>DC millivolts<\/td>\n<td>400.0 mV<\/td>\n<td>0.1 mV<\/td>\n<td>1.0% + 10<\/td>\n<\/tr>\n<tr>\n<td>Diode test<sup>2<\/sup><\/td>\n<td>2.000 V<\/td>\n<td>0.001 V<\/td>\n<td>10%<\/td>\n<\/tr>\n<tr>\n<td>Resistance<br \/>\n(Ohms)<\/td>\n<td>400.0 \u03a9<br \/>\n4.000 k\u03a9<br \/>\n40.00 k\u03a9<br \/>\n400.0 k\u03a9<br \/>\n4.000 M\u03a9<br \/>\n40.00 M\u03a9<\/td>\n<td>0.1 \u03a9<br \/>\n0.001 k\u03a9<br \/>\n0.01 k\u03a9<br \/>\n0.1 k\u03a9<br \/>\n0.001 M\u03a9<br \/>\n0.01 M\u03a9<\/td>\n<td>0.5% + 3<br \/>\n0.5% + 2<br \/>\n0.5% + 2<br \/>\n0.5% + 2<br \/>\n0.5% + 2<br \/>\n1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>Capacitance<sup>3<\/sup><\/td>\n<td>40.00 nF<br \/>\n400.0 nF<br \/>\n4.000 \u03bcF<br \/>\n40.00 \u03bcF<br \/>\n400.0 \u03bcF<br \/>\n1000 \u03bcF<\/td>\n<td>0.01 nF<br \/>\n0.1 nF<br \/>\n0.001 \u03bcF<br \/>\n0.01 \u03bcF<br \/>\n0.1 \u03bcF<br \/>\n1 \u03bcF<\/td>\n<td>2% + 5<br \/>\n2% + 5<br \/>\n5% + 5<br \/>\n5% + 5<br \/>\n5% + 5<br \/>\n5% + 5<\/td>\n<\/tr>\n<tr>\n<td>AC current \u03bcA<br \/>\n(40 Hz to 400 Hz)<\/td>\n<td>400.0 \u03bcA<br \/>\n4000 \u03bcA<\/td>\n<td>0.1 \u03bcA<br \/>\n1 \u03bcA<\/td>\n<td>1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>AC current mA<br \/>\n(40 Hz to 400 Hz)<\/td>\n<td>40.00 mA<br \/>\n400.0 mA<\/td>\n<td>0.01 mA<br \/>\n0.1 mA<\/td>\n<td>1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>AC current A<br \/>\n(40 Hz to 400 Hz)<\/td>\n<td>4.000 A<br \/>\n10.00 A<\/td>\n<td>0.001 A<br \/>\n0.01 A<\/td>\n<td>1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>DC current \u03bcA<\/td>\n<td>400.0 \u03bcA<br \/>\n4000 \u03bcA<\/td>\n<td>0.1 \u03bcA<br \/>\n1 \u03bcA<\/td>\n<td>1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>DC current mA<\/td>\n<td>40.00 mA<br \/>\n400.0 mA<\/td>\n<td>0.01 mA<br \/>\n0.1 mA<\/td>\n<td>1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>DC current A<\/td>\n<td>4.000 A<br \/>\n10.00 A<\/td>\n<td>0.001 A<br \/>\n0.01 A<\/td>\n<td>1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td>Backlight<\/td>\n<td colspan=\"3\">Yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><sup>1<\/sup>All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.<br \/>\n<sup>2<\/sup>Typically, open circuit test voltage is 2.0 V and short circuit current is &lt;0.6 mA.<br \/>\n<sup>3<\/sup>Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>Function<\/td>\n<td>Overload protection<\/td>\n<td>Input impedance (Nominal)<\/td>\n<td>Common mode rejection ratio<\/td>\n<td>Normal mode rejection ratio<\/td>\n<\/tr>\n<tr>\n<td>AC volts<\/td>\n<td>1000 V\u00a0<sup>1<\/sup><\/td>\n<td>&gt;10 M\u03a9 &lt;100 pF<\/td>\n<td>&gt;60 dB at dc,<br \/>\n50 Hz or 60 Hz<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>AC millivolts<\/td>\n<td>400 mV<\/td>\n<td>&gt;1M\u03a9, &lt;100 pF<\/td>\n<td>&gt;80 dB at 50 Hz or 60 Hz<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>DC volts<\/td>\n<td>1000 V\u00a0<sup>1<\/sup><\/td>\n<td>&gt;10 M\u03a9 &lt;100 pF<\/td>\n<td>&gt;100 dB at dc,<br \/>\n50 Hz or 60 Hz<\/td>\n<td>&gt;60 dB at 50 Hz or 60 Hz<\/td>\n<\/tr>\n<tr>\n<td>DC millivolts<\/td>\n<td>400 mV<\/td>\n<td>&gt;1M\u03a9, &lt;100 pF<\/td>\n<td>&gt;80 dB at 50 Hz or 60 Hz<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><sup>1<\/sup>\u00a010<sup>6<\/sup>\u00a0V Hz Max<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\">General specifications<\/td>\n<\/tr>\n<tr>\n<td>Maximum voltage between any terminal and earth ground<\/td>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<td>Display (LCD)<\/td>\n<td>4000 counts, updates 3\/sec<\/td>\n<\/tr>\n<tr>\n<td>Battery type<\/td>\n<td>2 AA, NEDA 15A, IEC LR6<\/td>\n<\/tr>\n<tr>\n<td>Battery life<\/td>\n<td>500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Temperature<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td>0 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage<\/td>\n<td>-30 \u00b0C to 60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Relative humidity<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Operating humidity<\/td>\n<td>Non-condensing (&lt;10\u00b0C)<br \/>\n\u226490% RH at 10 \u00b0C to 30 \u00b0C;<br \/>\n\u226475% RH at 30 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>40 M\u03a9 range<br \/>\n\u226480% RH at 10 \u00b0C to 30 \u00b0C;<br \/>\n\u226470% RH at 30 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Altitude<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td>2000 m<\/td>\n<\/tr>\n<tr>\n<td>Storage<\/td>\n<td>12,000 m<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient<\/td>\n<td>0.1 X (specified accuracy) \/\u00b0C (&lt;18 \u00b0C or &gt;28 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>Fuse protection for current inputs<\/td>\n<td>440 mA, 1000 V Fast Fuse, Fluke specified part only.<br \/>\n11A, 1000V Fast Fuse, Fluke specified part only.<\/td>\n<\/tr>\n<tr>\n<td>Size (H x W x L)<\/td>\n<td>183 x 91 x 49.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>455 g<\/td>\n<\/tr>\n<tr>\n<td>IP rating<\/td>\n<td>IP 40<\/td>\n<\/tr>\n<tr>\n<td>Safety<\/td>\n<td>IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2<\/td>\n<\/tr>\n<tr>\n<td>Electromagnetic environment<\/td>\n<td>IEC 61326-1: Portable<\/td>\n<\/tr>\n<tr>\n<td>Electromagnetic compatibility<\/td>\n<td>Applies to use in Korea only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Class A equipment (industrial broadcasting &amp; communication equipment)<sup>1<\/sup><br \/>\n<sup>1<\/sup>\u00a0This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or<br \/>\nuser should take notice of it. This equipment is intended for use in business environments and is not to be<br \/>\nused in homes.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<\/div>\n<footer id=\"fluke-product-display-footer\"><\/footer>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<footer id=\"site-footer\" class=\"inverse\">\n<div class=\"footer-top\">\n<div class=\"row\"><\/div>\n<\/div>\n<\/footer>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<div id=\"shopify-section-static-product-recommendations\" class=\"shopify-section product-recommendations--section\"><\/div>\n<div id=\"shopify-section-static-recently-viewed\" class=\"shopify-section recently-viewed--section\">\n<aside class=\"product-section--container product-recently-viewed--section\" aria-label=\"Recently viewed products\">\n<div class=\"product-recently-viewed-wrapper\">\n<div class=\"product-recently-viewed-header\"><\/div>\n<\/div>\n<\/aside>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>FLUKE DIGITAL MULTI METER MODEL15B+ Download FLUKE 15B+ 17B+ Data Sheet \u25cf\u00a0600V Cat III safety rating \u25cf\u00a050% bigger display with bright white backlight \u25cf\u00a0Voltage, resistance, continuity, capacitance \u25cf\u00a0Input terminal for ac and dc current measurements to 10A current \u25cf\u00a0Diode test, and Data hold Specifications: Fluke 15B+ Digital Multimeter Accuracy Specifications Accuracy is specified for 1 [&hellip;]\n","protected":false},"featured_media":24403,"template":"","meta":[],"product_cat":[210,169],"product_tag":[],"_links":{"self":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product\/24387"}],"collection":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/media\/24403"}],"wp:attachment":[{"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/media?parent=24387"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product_cat?post=24387"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/qariya.net\/en\/wp-json\/wp\/v2\/product_tag?post=24387"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}